Research facility II
- Home
- Faculty of Engineering & Technology
- Department of Biotechnology
- Research facility II
Research facility II
Agilent 1260 Infinity HPLC with PDA, FLD and RI detectors is utilized for separation, detection, and method development of analytes both qualitatively and quantitatively from biological and environmental samples.
The Core Research Facility II at the Department of Biotechnology, School of Bioengineering (SRMIST was set up as a sophisticated analytical equipment to provide scientific and technical services to research scholars and project students.
In this connection, state-of-the-art analytical and high-end instruments were planned to service the needs of the ever increasing number of undergraduate and postgraduate students and Research scholars with several requirements. This facility is made available to nearby peer academic institutions with nominal charges.
s.

Specifications
- High Performance Liquid Chromatography (HPLC) with PDA, FLD and RI detectors
- Liquid chromatography–Mass Spectrometry (LC-MS)
- Gas chromatography–Mass Spectrometry (GC-MS)
- Fourier-transform infrared spectroscopy (FTIR) with ATR
- UV-Visible Spectrophotometer (with nano drop)
- UV-Visible Microplate reader
- Minilyser (Homogenizer)
- Liquid Nitrogen Container – Cryo storage
- RT-qPCR
- Fluorometer and Luminometer
- Nano partical analyser
- B. Tech., and M. Tech.,academic laboratory purpose
- B. Tech., and M. Tech., project work
- Ph. D., Research scholars work
- Funded project research
- SRM Group of institutions
- Near by academic institutions
Profile
Shimadzu LC-MS, which is used to analyse the mass elucidation of nonvolatile sample types, such as polymers, natural products, small synthetic molecules and Environmental samples.
Agilent Technologies, 7890B GC with 5977A MSD – Analysis of volatile and semi-volatile mixtures from biological samples includes natural products etc. and environmental samples.
Agilent, Cary 600 series FTIR with KBr and ATR – Used for analysis of biological samples, organic and inorganic samples etc.
Agilent, Cary 60, UV-Vis spectrophotometer – wavelength range of 190–1100 nm, scanned in under 3 sec., micro volume sample holder.
Thermo Scientific, Multiskan UV-Vis microplate reader, wavelengths from 200 nm to 1000 nm, 96-well microplates, micro-volume DNA/RNA and protein analysis.
Thermo Scientific, Fluoroskan FL Microplate Fluorometer and Luminometer reader.
HORIBA, SZ-100, Particle size analysis is performed by dynamic light scattering (DLS) and zeta potential of a suspension
Bio-Rad, CFX96 Touch Real-Time PCR Detection System, six-channel (5 colors and 1 FRET channel)
Contact Persons
Dr. R.A. Nazeer
Professor and Head
hod.biotech.ktr@srmist.edu.in
Dr. R. Pachaiappan
Associate Professor
pachaiar@srmist.edu.in